Abstract

Various approaches have been developed to control wind tunnels, which are widely used in industrial applications. In this study, a mathematical model of the VTI Belgrade T-38 supersonic blowdown wind tunnel was used for numerical simulations. The tunnel operates from Mach 0.2 to Mach 4, and flow control was simulated at Mach 2. The tunnel’s highly time-varying nonlinear behavior makes it particularly challenging to control. To address this challenge, the governing equations were linearized, and the proportional–integral (PI) controller parameters were determined using the linearized model. For real-time supersonic testing, the classical PI approach with linearization was preferred over advanced controllers reported in the literature because it requires less computation and is easier to implement in the field. The PI parameters were obtained using the Cohen–Coon and Ziegler–Nichols tuning methods and then applied to the nonlinear model. The results show that the Cohen–Coon correction shortens the settling time and that overshoot in the nonlinear model is reduced to nearly zero.